Schedule 40 vs 80 Pipe Calculator

Compare Schedule 40 and Schedule 80 pipe dimensions side-by-side. Find outside diameter, inside diameter, and wall thickness for steel and PVC pipes from 1/2" to 12" NPS.

No Results Yet

Select a material and pipe size, then click "Compare Schedules" to see results.

Schedule 40 vs Schedule 80: What's the Difference?

The main difference between Schedule 40 and Schedule 80 pipe is wall thickness. Both schedules have the same outside diameter (OD) for a given nominal pipe size (NPS), but Schedule 80 has a thicker wall, resulting in a smaller inside diameter (ID) and higher pressure rating.

Schedule 40

  • Wall Thickness: Standard thickness
  • Inside Diameter: Larger (more flow capacity)
  • Pressure Rating: Lower than Schedule 80
  • Weight: Lighter
  • Cost: Less expensive
  • Applications: Residential plumbing, drainage, low-pressure systems

Schedule 80

  • Wall Thickness: Extra heavy thickness
  • Inside Diameter: Smaller (reduced flow capacity)
  • Pressure Rating: Higher than Schedule 40
  • Weight: Heavier
  • Cost: More expensive
  • Applications: Industrial processes, high-pressure systems, chemical plants

Important Note:

Schedule 80 pipe has approximately 10-30% less flow capacity than Schedule 40 due to its smaller inside diameter. This reduction in flow area must be considered when sizing piping systems.

Schedule 40 vs 80 Quick Comparison

Side-by-side comparison for popular pipe sizes showing the impact of Schedule 80's thicker walls.

NPSSchedule 40Schedule 80Comparison
IDWallIDWallID ReductionFlow Loss
1/2"0.622"0.109"0.546"0.147"12.2%23.0%
1"1.049"0.133"0.957"0.179"8.8%16.8%
2"2.067"0.154"1.939"0.218"6.2%12.0%
3"3.068"0.216"2.900"0.300"5.5%10.7%
4"4.026"0.237"3.826"0.337"5.0%9.7%
6"6.065"0.280"5.761"0.432"5.0%9.8%

Note: Flow loss percentage is based on the reduction in cross-sectional area from Schedule 40 to Schedule 80. This affects flow capacity and may require a larger pipe size to achieve the same flow rate.

How to Choose Between Schedule 40 and 80

Pressure Requirements

The most important factor in selecting between Schedule 40 and 80 is system pressure. Schedule 80 pipe can handle significantly higher pressures due to its thicker walls.

  • Schedule 40: Suitable for low to medium pressure applications (up to ~150 psi for smaller sizes)
  • Schedule 80: Required for high pressure applications (up to ~300+ psi for smaller sizes)
  • Always consult pressure rating charts for specific sizes and materials
  • Apply appropriate safety factors per code requirements

Application Guidelines

Use Schedule 40 For:

  • Residential water supply systems
  • Drainage and waste systems
  • Irrigation and sprinkler systems
  • Low-pressure HVAC applications
  • Gravity-fed systems
  • Cost-sensitive projects

Use Schedule 80 For:

  • High-pressure industrial processes
  • Chemical processing plants
  • Compressed air systems
  • Areas subject to physical damage
  • Exterior applications requiring impact resistance
  • Critical systems requiring extra safety margin

Code Compliance

Building codes and industry standards often specify minimum pipe schedules for specific applications. Always verify compliance with:

  • Local building codes and plumbing codes
  • ASME B31.3 (Process Piping)
  • ASME B31.1 (Power Piping)
  • International Plumbing Code (IPC)
  • Uniform Plumbing Code (UPC)

Cost Considerations

Schedule 80 pipe typically costs 25-50% more than Schedule 40 due to the additional material. Consider total system cost including:

  • Pipe material cost
  • Fitting and valve costs (Schedule 80 fittings are more expensive)
  • Installation labor (heavier pipe may require more labor)
  • Support structure requirements (heavier pipe needs stronger supports)
  • Long-term maintenance and safety benefits

Understanding Pipe Schedules

What is Pipe Schedule?

Pipe schedule is a standardized system for specifying pipe wall thickness. The schedule number is approximately related to the formula: Schedule = 1000 × P / S, where P is the internal pressure (psi) and S is the allowable stress (psi).

Common schedules include 5, 10, 20, 30, 40, 60, 80, 100, 120, 140, and 160, with Schedule 40 and Schedule 80 being the most widely used for general applications.

Why Same OD, Different ID?

All pipes of the same nominal size have the same outside diameter (OD) regardless of schedule. This standardization allows for interchangeability of fittings and supports. The inside diameter (ID) decreases as the schedule number increases because the wall gets thicker while the OD stays constant.

Example for 2" NPS pipe:
• OD for all schedules: 2.375"
• Schedule 40: Wall = 0.154", ID = 2.067" (2.375" - 2×0.154")
• Schedule 80: Wall = 0.218", ID = 1.939" (2.375" - 2×0.218")

Schedule Formula

The relationship between schedule number and wall thickness is standardized in ASME B36.10M for steel pipe and ASTM D1785 for PVC pipe. The schedule system was developed to provide a consistent method for specifying pipe strength across different sizes.

Industry Standards

Steel Pipe Standards

  • ASME B36.10M: Welded and Seamless Wrought Steel Pipe
  • ASTM A53: Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless
  • ASTM A106: Seamless Carbon Steel Pipe for High-Temperature Service

PVC Pipe Standards

  • ASTM D1785: PVC Plastic Pipe, Schedules 40, 80, and 120
  • ASTM D2241: PVC Pressure-Rated Pipe (SDR Series)
  • NSF/ANSI 61: Drinking Water System Components

Related Pipe Size Charts

Related Calculators

Engineering Notes & Disclaimer

Standards Compliance: All dimensions in this calculator are based on ASME B36.10M (Welded and Seamless Wrought Steel Pipe) and ASTM D1785 (PVC Plastic Pipe, Schedules 40, 80, and 120) standards.

Pressure Ratings: Pressure ratings vary by material, temperature, and size. Always consult manufacturer specifications and applicable codes for pressure rating information.

Flow Calculations: Flow capacity reductions are based on cross-sectional area differences and do not account for friction factor changes or specific application requirements.

Material Selection: Schedule 40 and Schedule 80 designations are primarily used for steel and PVC pipe. Copper uses Type K/L/M designations, and HDPE uses SDR ratings. This calculator focuses on Schedule 40/80 comparisons for materials that use this system.

Professional Verification: This calculator is for reference and preliminary design only. All piping systems must be designed and verified by qualified engineers in accordance with applicable codes, standards, and local regulations. Always verify dimensions and specifications with manufacturer data sheets.

Liability: The user assumes all responsibility for proper application of this information. PipeSizing.net and its operators are not liable for any damages or losses resulting from the use of this calculator.